✓ Teknologi AGM majeng, lan operasi bebas Pangopènan;
✓ Terminal akses ngarep kanthi jembar standar kanggo rak ETSI 19 "lan 23";
✓ wadhah ABS tahan geni;
✓ Umur layanan ngambang dawa 10 taun;
✓ Low self discharge <3%.
STANDAR sing dituruti
IEC 60896-21/22
JIS C8704 YD/T799
BS6290 bagean 4
GB/T 19638 CE
dawa (mm) | 507±1 |
Jembar (mm) | 110±1 |
Dhuwur (mm) | 223±1 |
Dhuwur Total (mm) | 228±1 |
Bobot (kg) | 29,4±3% |
Tegangan nominal | 12V (6 sel per unit) | |||
Desain Ngambang Urip @25℃ | 10 Taun | |||
Nominal Capacity @25℃(10 hour rate@10.0A,10.8V) | 100 Ah | |||
Kapasitas @25 ℃ | Tingkat 20 jam (5.3A, 10.8V) tingkat 5 jam (17.6A, 10.5V) Tingkat 1 jam (63.8A, 9.6V) | 106Ah88.0Ah63.8Ah | ||
Rintangan internal | Baterei Diisi Daya Penuh @ 25 ℃ | ≤5.8mΩ | ||
Suhu sekitar | Discharge ChargeStorage | -15 ℃ ~ 45 ℃ -15 ℃ ~ 45 ℃ -15 ℃ ~ 45 ℃ | ||
Max.Discharge Saiki@25 ℃ | 600A(5s) | |||
Kapasitas kena pengaruh Suhu (10 jam) | 40 ℃ 25 ℃ 0 ℃ -15 ℃ | 105%100%85% 65% | ||
Self-Discharge@25 ℃ saben Wulan | 3% | |||
Ngisi daya (Tegangan Konstan) @25 ℃ | Gunakake siyaga | Arus Pengisian Awal Kurang saka 25A Tegangan 13.6-13.8V | ||
Gunakake Siklus | Arus Pengisian Awal Kurang saka 25AVoltage 14.4-14.9V |
Discharge Arus Konstan saben Sel (Amperes ing 25°C)
FV / Wektu | 10 min | 15 min | 30 min | 45 min | 1h | 2h | 3h | 5h | 8h | 10h | 20h |
1.60V | 232.5 | 180.5 | 111.3 | 80.5 | 63.8 | 37.5 | 27.6 | 18.6 | 12.7 | 10.5 | 5.55 |
1.65V | 215.1 | 170.5 | 105.7 | 77.4 | 61.9 | 36.3 | 26.7 | 18.3 | 12.6 | 10.3 | 5.50 |
1.70V | 199.5 | 160.1 | 101.8 | 74.6 | 59.5 | 35.3 | 26.0 | 17.9 | 12.4 | 10.2 | 5.44 |
1.75V | 186.3 | 150.0 | 96.5 | 71.3 | 57.1 | 34.4 | 25.4 | 17.6 | 12.2 | 10.1 | 5.39 |
1.80V | 167.6 | 140.7 | 93.1 | 68.7 | 55.1 | 33.1 | 24.6 | 17.2 | 12.0 | 10.0 | 5.30 |
Discharge Konstan Daya saben Sel (Watts ing 25°C)
FV / Wektu | 10 min | 15 min | 30 min | 45 min | 1h | 2h | 3h | 5h | 8h | 10h | 20h |
1.60V | 418.2 | 345.1 | 211.1 | 152.9 | 122.4 | 71.1 | 52.7 | 35.9 | 24.8 | 20.5 | 10.7 |
1.65V | 391.4 | 330.2 | 201.9 | 147.7 | 119.1 | 69.2 | 51.3 | 35.3 | 24.6 | 20.3 | 10.6 |
1.70V | 366.5 | 307.7 | 193.6 | 143.0 | 115.0 | 67.6 | 50.1 | 34.8 | 24.3 | 20.1 | 10.5 |
1.75V | 344.9 | 288.7 | 184.3 | 137.3 | 110.8 | 66.0 | 49.1 | 34.3 | 24.0 | 19.9 | 10.4 |
1.80V | 312.2 | 271.0 | 176.8 | 132.7 | 107.2 | 63.8 | 47.7 | 33.6 | 23.7 | 19.8 | 10.3 |
Cathetan: Data ing ndhuwur minangka nilai rata-rata, lan bisa dipikolehi sajrone 3 siklus pangisian daya/discharge.Iki dudu nilai minimal.Desain / spesifikasi sel lan baterei tundhuk modifikasi tanpa kabar.Hubungi CSBattery kanggo informasi paling anyar.
Komponen | Plate positif | Plat negatif | Wadhah & Tutup | Katup safety | Terminal | Pamisah | Elektrolit | Pilar segara |
Fitur | Kandel dhuwur Sn kurang Ca kothak karo tempel khusus | Kothak Pb-Ca sing seimbang kanggo rekombinasi efisiensi | Tahan geni ABS (UL94-V0 opsional) | Flame Si-Rubber lan tahan tuwa | Sisipan Tembaga Wanita M6 (torsi: 3~4N.m | AGM majeng separator kanggo desain sel tekanan dhuwur | Dilute asam sulfat kemurnian dhuwur | Segel resin epoksi rong lapisan |